BKPZZ - TEFLON TOPCOATS (455-117)
- MSDS: BKPZZ
- Manufacturer: E I DUPONT DE NEMOURS AND CO
- Product Name: TEFLON TOPCOATS (455-117)
- National Stock Number: 8010-00N015347
Product Identification
Product ID:TEFLON TOPCOATS (455-117)
MSDS Date:01/01/1987
FSC:8010
NIIN:00N015347
MSDS Number: BKPZZ
Responsible Party
WILMINGTON, DE 19898
US
Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)
Info Phone: 800-441-7515
Cage: 0ERJ7
Contractor
Telephone: 800-441-7515;800-441-9442
Cage: 18873
Ingredients
BE PROPERLY VENT. AT TEMPS ABOVE 400C (750F) SM
RTECS: 9999999ZZ
AS TEMP INCR. HYDROGEN FLUORIDE IS TOXIC & CAN
RTECS: 9999999ZZ
CONC CAN CAUSE LUNG DMG, PULM EDEMA/BURNS. SOME
RTECS: 9999999ZZ
AND ATTN MUST BE GIVEN TO EXHAUST LOCATIONS. OXIDES
RTECS: 9999999ZZ
FLUOROPOLYMER SOLIDS
2-(2-BUTOXY ETHOXY)-ETHANOL (DIETHYLENE GLYCOL MONOBUTYL
CAS: 112-34-5
RTECS: KJ9100000
0.01
CAS: 102-71-6
RTECS: KL9275000
5
CAS: 64742-95-6
OCTYLPHENOXYPOLYETHOXYETHANOL (NON-IONIC SURFACTANT)
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
IRON OXIDE
CAS: 1309-37-1
RTECS: NO7400000
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5 MG/M3(FE),B2; 9293
CONSCIOUSNESS. CAUSES EYE CORR & PERM
RTECS: 9999999ZZ
IRRIT. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT &
RTECS: 9999999ZZ
NAUS & LOSS OF CONSCIOUSNESS. RPTS HAVE ASSOC RPTD &
RTECS: 9999999ZZ
DMG. (ING 5) CONT MAY CAUSE SKIN IRRIT
RTECS: 9999999ZZ
KNOWN HAZ W/NORMAL INDUSTRIAL USE. IN A LIFETIME
RTECS: 9999999ZZ
EXPOSED TO 250 MG/M3 RESP TDUST. ANALYSIS OF
RTECS: 9999999ZZ
CLEARANCE MECHANISM WAS OVERWHELMED & THAT THE
RTECS: 9999999ZZ
TO WORKPLACE. (ING 7) MAY CAUSE IRRIT OF MUC MEMB.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: NORMALLY NOT HAZ. THESE PRODS
CONTAIN SM AMTS OF SOLV AS DESCRIBED BELOW. SKIN/EYE: MAY CAUSE
IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT
W/DISCOMFORT & DERMAT. OTHER POTEN TIAL HAZ INCL: (ING 1) SEE HAZ
DECOMP PRODS. (ING 2) MAY CAUSE EYE IRRIT W/DISCOMFORT, TEARING OR
(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:HLTH HAZ: BLURRED VISION. CONT MAY CAUSE SKIN
IRRIT W/DISCOMFORT/RASH. CAN BE ABSORBED THRU SKIN IN HARMFUL AMTS.
MAY CAUSE ABNORMAL KIDNEY FUNCTION. (ING 3) OVEREXP MAY CAUSE EYE,
NOSE & THROAT IRRIT . RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT &
DERMAT. MAY CAUSE CNS EFTS SUCH AS DIZZ, HDCH, NAUS & LOSS OF (SEE
ING 8)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: IF AFFECTED BY INHAL OF VAP/SPRAY MIST, REMOVE TO
FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF
BRTHG DIFFICULTY PERSISTS/OCCURS LATER, CALL MD. SKIN/EYE: IMMED
FLUSH W/PLENT Y OF WATER FOR AT LEAST 15 MIN; CALL MD. SKIN: WASH
WITH SOAP & WATER. IF IRRIT OCCURS, CALL MD. INGEST: GI DISTRESS.
IN UNLIKELY EVENT OF INGEST, CALL MD IMMED & HAVE NAMES OF INGRED
AVAIL.
Fire Fighting
Flash Point:NONE
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER FROM FOG NOZZLES MAY BE USED TO COOL CLSD CNTNRS TO PVNT
PRESS BUILD-UP.
Unusual Fire/Explosion Hazard:HYDROGEN FLUORIDE IS RELEASED DURING A
FIRE.
Accidental Release
Spill Release Procedures:VENT AREA. REMOVE SOURCES OF IGNITION. AVOID
SKIN CONTACT AND BREATHING OF VAPOR. CONFINE AND REMOVE WITH INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE LABEL PREC. KEEP AWAY FROM
HEAT, SPARKS & FLAME. CLOSE CNTNR AFTER USE. GROUND CNTNRS WHEN
POURING. DO NOT STORE ABOVE 120F.
Other Precautions:EXPLOSIVE REACTION MAY OCCUR ABOVE 796F WITH FINELY
DIVIDED FLUOROCARBON AND METAL POWDER (ALUMINUM OR MAGNESIUM).
OPERATIONS SUCH AS GRINDING, BUFFING OR GRIT BLASTING MAY GENERATE
SUCH MIXTURES. KEE P WET. USE ADEQUATE VENT TO CONTROL.
Exposure Controls
Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR A PROPERLY
FITTED NIOSH/MSHA APPRVD VAP/PARTICULATE RESP FOR USE WITH PAINTS
DURING APPLICATN & UNTIL ALL VAPS AND SPRAY MIST ARE EXHAUSTED.
FOLLOW RESP MFR DIRECTIONS FOR RESP USE.
Ventilation:PROVIDE SUFFICIENT VENT IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING AND SMOKING.
Supplemental Safety and Health
% VOLAT: 46.3-49.1 (WT). HAZ DECOMP PROD: THESE SYMP DO NOT ORDINARILY
OCCUR UNTIL SEV HRS AFTER EXPOS & PASS WITHIN 36-48 HRS. EFTS ARE
NOT CUMULATIVE. EXPOS USUALLY RESULTS FROM SMOKING TOBACCO/CIGA
RETTES CONTAMINATED W/FLUOROCARBON DURING HANDLING/FROM BRTHG VAPS
EMITTED DURING BAKING. DO NOT EXCEED (SEE ING 15)
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGRED
Vapor Density:>AIR
Spec Gravity:1.42
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:APPRECIABLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:EXPOS TO TEFLON DECOMP PRODS CAN
CREATE INFLUENZA-LIKE SYMP, COMMONLY REFERRED TO AS POLYMER FUME
FEVER. (SEE SUPP DATA)
Disposal
Waste Disposal Methods:DO NOT ALLOW MATL TO CONTAMINATE GROUND WATER
SYSTEMS. SEND TO HAZ WASTE WATER TREATMENT PLANT OR INCINERATE
ABSORBED MATL IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REQUIREMENTS. DO NOT INCINERATE I N CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.